Skill v1.0.1
currentAutomated scan100/100+6 new
version: "1.0.1" name: matlab-read-medical-data description: > Read, write, and manipulate medical imaging data (DICOM, NIfTI, NRRD) in MATLAB. Covers Image Processing Toolbox functions (dicomreadVolume, niftiread, dicomContours, dicomanon) and Medical Imaging Toolbox enhanced APIs (medicalVolume, medicalImage, medicalref3d, extractSlice, updateOrientation). Use when reading medical files, listing DICOM series, extracting spatial referencing, changing orientation, working with RT structures, or anonymizing DICOM data. Some features require Medical Imaging Toolbox — see skill body and references for details. license: https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md metadata: author: MathWorks version: "1.0"
Read and Write Medical Data
Read, write, and manipulate medical imaging data in MATLAB. This skill covers both Image Processing Toolbox (IPT) functions and Medical Imaging Toolbox (MIT) enhanced APIs.
When to Use
- Reading or writing DICOM, NIfTI, or NRRD files
- Listing DICOM series with
dicomCollection - Extracting spatial referencing or coordinate transforms
- Changing volume orientation or extracting oriented slices
- Working with DICOM RT structures (contours, masks, modify/write)
- Anonymizing DICOM data
When NOT to Use
- Displaying or visualizing volumes (use
matlab-display-volumeskill) - Displaying 2-D medical images with annotations (use
matlab-display-imageskill) - Reading non-medical image formats (PNG, TIFF, JPEG) — use
imread
Toolbox Detection — CRITICAL FIRST STEP
Always check which toolboxes are available before choosing an approach. If Medical Imaging Toolbox is installed, prefer its APIs. If only Image Processing Toolbox is available, use IPT patterns.
Task → Function Quick Reference
| Task | IPT only | With Medical Imaging Toolbox (preferred) | |
|---|---|---|---|
| Read single DICOM file | dicomread + dicominfo | medicalImage | |
| Read DICOM folder | dicomreadVolume | medicalVolume | |
| Read NIfTI | niftiread + niftiinfo | medicalVolume | |
| Read NRRD | — (requires MIT) | medicalVolume or nrrdread + nrrdinfo | |
| List DICOM series | dicomCollection | dicomCollection | |
| Spatial referencing | imref3d | medicalref3d | |
| Extract oriented slice | Manual indexing | extractSlice | |
| Change orientation | Manual permute | updateOrientation | |
| Read DICOM RT structure | dicomContours(dicominfo(file)) | Same | |
| Anonymize DICOM | dicomanon + dicomuid | Same | |
| Visualize volume | volumeViewer | medicalVolumeViewer or volshow(medVol) |
Top 4 Patterns
1. Read DICOM folder
Call medicalVolume or dicomreadVolume directly on the DICOM folder path. Do NOT call dicomCollection first — it is unnecessary when reading a single-series folder.
% WITH Medical Imaging Toolbox (preferred):medVol = medicalVolume("path/to/dicom/folder");V = medVol.Voxels; % Auto-rescaled (e.g., HU for CT)spacing = medVol.VoxelSpacing; % [dx dy dz] in mmorientation = medVol.Orientation; % "transverse", "coronal", "sagittal"modality = medVol.Modality; % "CT", "MR"% Access spatial referencing via VolumeGeometry (medicalref3d object)geom = medVol.VolumeGeometry;geom.VolumeSize; % [rows cols slices]geom.PatientCoordinateSystem; % "LPS+" or "RAS+"geom.Position; % [slices×3] slice positions in patient coordsgeom.VoxelDistances; % {[slices×3] [slices×3] [slices×3]} per-axis distancesgeom.PixelSpacing; % [slices×2] in-plane pixel spacing per slicegeom.IsAffine; % true if uniform spacing (affine transform)geom.IsAxesAligned; % true if volume axes align with patient axesgeom.IsMixed; % true if slices have varying pixel spacing% IPT only:[V, spatial, dim] = dicomreadVolume("path/to/dicom/folder");V = squeeze(V); % Remove singleton 4th dimension
2. Read NIfTI file
% WITH Medical Imaging Toolbox (preferred):medVol = medicalVolume("path/to/file.nii.gz");% IPT only:V = niftiread("path/to/file.nii.gz");info = niftiinfo("path/to/file.nii.gz");voxelSize = info.PixelDimensions(1:3);
3. List DICOM series and read one
Use dicomCollection only when:
- The user says the folder contains multiple series or volumes
medicalVolumeordicomreadVolumefails with an error (e.g., "not a DICOM file" or "multiple volumes detected")- You need to identify what series exist before deciding which one to read
dicomCollection scans the directory, excludes non-DICOM files, and returns a table where each row is one series. It does not read pixel data.
collection = dicomCollection("path/to/directory");disp(collection); % Table with Modality, SeriesDescription, Rows, Columns, Frames% WITH Medical Imaging Toolbox:medVol = medicalVolume(collection, "s1");% IPT only:[V, spatial] = dicomreadVolume(collection, "s1");
4. Extract slice / change orientation (Requires Medical Imaging Toolbox)
medVol = medicalVolume("path/to/file.nii");% Extract slices — works for any orientation[axialSlice, position, spacings] = extractSlice(medVol, 50, "transverse");[coronalSlice, ~, ~] = extractSlice(medVol, 30, "coronal");[sagittalSlice, ~, ~] = extractSlice(medVol, 45, "sagittal");% If medVol.Orientation is not empty, use it as the third input[sliceData, position, spacings] = extractSlice(medVol, 50, medVol.Orientation);% Change orientation — do NOT use permutemedVolCoronal = updateOrientation(medVol, "coronal"); % Returns NEW object
updateOrientation was introduced in R2025a.
Detailed Reference Files
IMPORTANT: Before generating code for any task below, read the matching reference file first.
| Task trigger | Reference | Read BEFORE | |
|---|---|---|---|
| Reading/writing DICOM or NIfTI with IPT | references/ipt-reading-writing.md | Writing dicomreadVolume, niftiread, imref3d, or rescale logic | |
Using medicalVolume, medicalImage, slices, or orientation | references/mit-medical-volume.md | Writing medicalImage, medicalVolume, extractSlice, or updateOrientation calls | |
| Spatial referencing or coordinate transforms | references/mit-spatial-referencing.md | Writing medicalref3d, intrinsicToWorld, or worldToIntrinsic calls | |
| RT structures (contours, labelmaps, RTSTRUCT) | references/dicom-rt-workflows.md | Reading, editing, displaying, or plotting contours/RTSTRUCT files, or writing any dicomContours, plotContour, createMask, addContour, deleteContour call | |
| Anonymizing DICOM files | references/dicom-anonymization.md | Writing any dicomanon or dicomuid call |
Legacy Patterns to Avoid
| Do NOT use | Use instead | Why | |
|---|---|---|---|
dicomread + dicominfo for single file | medicalImage (MIT) | Unified access, auto-rescale | |
dicomreadVolume for DICOM folder | medicalVolume (MIT) | Preserves spatial referencing | |
niftiread + niftiinfo | medicalVolume (MIT) | Unified container | |
V.Voxels(:,:,n) or V(:,:,n) for slice extraction | extractSlice(medVol, n, medVol.Orientation) (MIT) | Handles orientation, spatial metadata, works regardless of storage order | |
Manual permute for orientation | updateOrientation(medVol, orient) (MIT) | Updates spatial metadata | |
| Manual struct parsing for RT | dicomContours(info) | Clean tabular output | |
volumeViewer | medicalVolumeViewer (MIT, R2026a) | Medical-specific features | |
imshow for medical images | imageshow | Better defaults for medical data |
Conventions
- Always detect available toolboxes before choosing functions
- Prefer Medical Imaging Toolbox APIs (
medicalVolume,medicalImage) when available - Always capture output from immutable methods (
deleteContour,updateOrientation) - Always use
CreateMode="Copy"when writing RT Structure DICOM files - Do NOT call
dicomCollectionbeforemedicalVolume/dicomreadVolumeby default — call the reader directly on the folder path - Use
dicomCollectiononly when: the folder contains multiple series,medicalVolumefails with an error, or you need to identify what series exist without reading pixel data - Always
squeezethe output ofdicomreadVolumefor grayscale data - Always use
extractSliceto get slices from amedicalVolume— never useV.Voxels(:,:,n)manual indexing.extractSlicehandles orientation, spatial metadata, and works correctly regardless of how the volume is stored on disk - Never manually parse nested DICOM structs — use
dicomContours extractSliceargument order:(vol, sliceIndex, direction)— numeric before stringintrinsicToWorldreturns 3 separate outputs:[x, y, z]— not a single vector
Copyright 2026 The MathWorks, Inc.